Control Head Preventive Maintenance

Overview

This page is intended to guide the reader through CCI’s recommended redundancy testing for Control Heads.

Card Concepts Inc takes no responsibility for data loss due to human error, hardware failure, or other such circumstances.

Requirements

  • Access to front and back of all X-Changer cabinets.

Step-by-step guide

Frequency: Every six months

Warning

  1. Starting at the front, check for 3 green voltage lights.

    1. Red lights are an indication of either a short on a line or a problem with the card dispenser, card readers or bar code scanner or no power to the Control Head.

  2. Using a Manager Card, or an Attendant Card with the appropriate permissions, insert the card into one of the X-Changers.

  3. Go to Maintenance then Store Status.

  4. Find out which X-Changer is running WCRD in Backup Mode. 

    Backup Mode.png
  5. From the X-Changer running in Backup Mode, power down the computer and unplug cables for lines 0 - 4 or 0 - 5 from the Control Head then disconnect the cable connected to 'Other Value Center'.  

  6. Go back to Store Status and find out which X-Changer is running WCRD in Master Mode.

  7. Make sure there are no Problem Readers and that all machines have good poll counts. 

    1. If there aren’t any Problem Readers and the poll counts look normal, plug cables for lines 0 - 4 or 0 - 5 back into the Control Head and reconnect the cable to 'Other Value Center'.

    2. If there are Problem Readers present, write down the reader numbers so you can compare them after checking the other X-Changer.

      1. You can troubleshoot them by following .

  8. Remove your card from the X-Changer and power on the Backup Mode computer.

  9. Once the LaundryCard application starts, wait an additional two minutes to allow the background processes to start up as well.

  10. Repeat steps 1 - 8 for the X-Changer that is in WCRD Control Mode.

    1. During this process, the X-Changer that is in Backup Mode will take over and become Control Mode. This may take up to five minutes. Wait until the X-Changer is in Control Mode before verifying if there are Problem Readers.