_984

 I-T0086

Part #: C-5265

Desc 1: Machine Start Harness

Desc 2: Alliance MC10 Control

   Qty: 1

Part #: C-5266

Desc 1: 6" 18 AWG wire

Desc 2: Jumper for ALS MC10 Control

   Qty: 1

  1. Connect the red wires from the C-5265 Machine Start Harness to the red and green terminal quick connects from the terminal block mounted on the coin vault. Pairing does not matter.

  2. Run the black wires from the C-5265 Machine Start Harness to the SoapLink 24v relay board located on the back of the machine.

  3. Connect black wires from the C-5265 Machine Start Harnessto RO1 and JO1. Pairing does not matter. (See below image for reference.)

  4. Connect the ends of C-5266 Jumper to RO11 and QO3. (See below image for reference.)

    C-5265 SoapLink Wiring Ref-20240125-044427.png