_982

 I-M0210

Part #: C-0975

Desc 1: LC/F1 Quantum Touch Bracket

Desc 2:

   Qty: 1

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

  1. Disconnect wires connected to vault service switch and bridge connection using C-5365 Bypass Harness.

  2. Remove the front control panel cover and pull panel away from machine exposing the factory plate / Coin Drop.

  3. Loosen the two (2) left retaining screws (Green) and remove the remaining screws on the bracket (Blue) and slide the bracket off the machine.

    QT_Mount_Step03-20240125-061006.jpg
  4. Slide the C-6965 QT Mounting Bracket onto the loose screws and tighten. Add remaining screws to the corresponding holes on the bracket and tighten.

    QT_Mount_Step04-20240125-061007.jpg
  5. Re-secure the front panel to the machine.

  6. Attach the C-5414 Reader Bracket to the C-6965 QT Mounting Bracket using C-5702 Chase Nipple and C-5703 Nut.

    20201214_090154.jpg20201214_090227.jpg
  7. Feed all reader harnesses through the center hole.

    20201214_095800.jpg