0429 Reader Install Guide

0429 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer
Manufacturer: Laundrylux
Make: Wascomat
Model Length: 10 to 11

Associated Models


WHWF09810DC
WHWF09810M
WHWF09810NM

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Install Mounting Hardware

 I-M0003

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

 I-M0010

Part #: C-5801

Desc 1: F1 Reader Mounting Kit

Desc 2: Front

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F1 Reader Mounting Guide for further instructions.

Instructions do not exist for Kit I-M0031

Instructions do not exist for Kit I-M0087

 I-M0135

Part #: C-5801

Desc 1: F1 Reader Mounting Kit

Desc 2: Front

   Qty: 1

  1. Place the C-5700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0136

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to FasCard Mounting Guide for further instructions.

 I-M0173

Part #: C-6801

Desc 1: F2/F3 Reader Mounting Kit

Desc 2: Universal

   Qty: 1

Part #: C-0941

Desc 1: Vault Cover

Desc 2: 3-7/8" x 3-1/2"

   Qty: 1

Part #: C-5033

Desc 1: Label

Desc 2: 4-5/8" x 3-1/2"

   Qty: 1

  1. Remove existing coin box.

    1. Optional: Apply C-5033 Label over coin drop opening.

  2. Bend the side tabs of the C-0941 Vault Cover outward and install into the coin vault. The tabs should snap into place securing the bracket.

  3. Place the C-6700-TEMP Drill Template on the desired mounting location.

  4. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  5. Refer to FasCard F2/F3 Reader Installation Guide - Front Mount for further instructions.

 I-M0216

Part #: C-6802

Desc 1: FLEX RF Reader Mounting Kit

Desc 2:

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

 I-M0250

Part #: C-6802

Desc 1: FLEX RF Reader Mounting Kit

Desc 2:

   Qty: 1

  1. Place the C-6700-TEMP Drill Template on the desired mounting location.

  2. Verify included harnesses will reach desired location without encountering interference from internal machine components.

  3. Refer to F2/F3 Mounting Guide for further instructions.

Instructions do not exist for Kit I-M0269

Connect Power

 I-P0007

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 2

Part #: C-5336

Desc 1: Power Adapter Harness

Desc 2: Dexter Stack

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the FasCard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

    1. 120vac: Connect the blue wire to L1 and the brown wire to N.

    2. 240vac: Connect the blue wire to L1 and the brown wire to L2.

    3. Secure the green wire to the ground screw.

  2. Connect the C-5336 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Coin Sense Harness

 I-S0014

Part #: C-5352

Desc 1: Coin Sense Harness

Desc 2: Wascomat Crossover

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-5352 Coin Sense Harness to the harness connected to the Coin Drop.

 I-S0041

Part #: C-6352

Desc 1: Coin Sense Harness

Desc 2: Wascomat Crossover

   Qty: 1

  1. Disconnect the Coin Drop from the Machine Control Assembly.

  2. Connect the C-6352 Coin Sense Harness to the harness connected to the Coin Drop.

Connect Machine Interface Harness

 I-T0034

Part #: C-0129

Desc 1: Machine Start Harness

Desc 2: Wascomat Crossover

   Qty: 1

  1. Connect the C-0129 Machine Start Harness to the Coin 1 connector on the Machine Control Assembly.

 I-T0062

Part #: C-5355

Desc 1: Machine Start Harness

Desc 2: Crossover

   Qty: 1

  1. Connect the C-5355 Machine Start Harness to the CN4 Payment Device Connection on the Machine Control Assembly
    NOTE: On top-load machines, the CN4 connection is located inside the metercase.

Connect and Mount Reader

 LaundryCard Reader (C-0100, C-0101, C-0102, C-0103)

  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the the Cat5 cables running to and from the adjacent machines to ports labeled 3 (Line Connection Ports) as shown in the image above.

  5. Secure the LaundryCard reader to the bracketry using included hardware.

 LaundryCard L2 Reader (C-0103-L2)

L2_Port_Guide.png
  1. Feed remaining harness ends through mounting bracket.

  2. For serial setups:

    1. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  3. For coin pulse setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Power Harness to port 1.

  5. Secure the L2 reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F1 Reader (C-5001)

  1. Feed remaining harness ends through the mounting hole as described in the F1 Reader Mounting Guide.

  2. Connect the free end of the Machine Start Harness to port 1 (Serial Connection Port) as shown in the image above.

  3. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Extension Harness to port 4 (Power Harness Connection Port) as shown in the image above.

  6. Secure the FasCard reader to base as described in the F1 Reader Mounting Guide.

 F2/FLEX Reader (C-5401, C-5402, C-5402E)

  1. Feed remaining harness ends through the mounting hole as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

  2. For Serial Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

    2. Connect the free end of the Machine Start Harness to port 5 (Serial Connection Port) as shown in the image above.

  3. For Pulse Setups:

    1. Connect the free end of the Machine Start Harness to port 2 (Pulse Connection Port) as shown in the image above.

  4. Connect the free end of the Coin Sense Harness to port 3 (Coin Sense Harness Connection Port) as shown in the image above.

    1. For dual coin drop setups connect the secondary Coin Sense Harness to port 4 (Coin Sense Harness Connection Port) as shown in the image above.

  5. Connect the free end of the Power Harness to port 1.

  6. Secure the FasCard reader to base as described in FasCard F2/F3 Reader Installation Guide - Front Mount.

 F3 Reader (C-5520, C-5520E)

TODO