_752

 I-M0041

Part #: C-0015

Desc 1: Label

Desc 2: Reader Cover Label

   Qty: 1

Part #: C-0032

Desc 1: Label

Desc 2: ADC Coin Drop

   Qty: 1

Part #: C-0133

Desc 1: Standoff

Desc 2: 8-32" x 1-1/2" - Hex

   Qty: 2

Part #: C-0141

Desc 1: Screw

Desc 2: 8-32 x 1-1/2" - Cap

   Qty: 2

Part #: C-0925A

Desc 1: Mounting Bracket

Desc 2: For Coin Vault Mounting

   Qty: 1

Part #: C-0925B

Desc 1: Mounting Bracket

Desc 2: For Coin Vault Mounting

   Qty: 1

Part #: C-0926

Desc 1: Drop Cover

Desc 2: American 330

   Qty: 1

Part #: C-1044N

Desc 1: Nut

Desc 2: M3 - Kep

   Qty: 4

  1. Remove existing coin box and coin drop.

  2. Insert the C-0925A Mounting Bracket into the Coin Vault. Orient the Mounting Bracket so that the threaded studs face outward.

  3. Attach the C-0133 Standoffs to the threaded studs on the Mounting Bracket.

  4. Place C-0925B Mounting Bracket Cover over the Coin Vault so that the opening for the screws line up with the Standoffs.

  5. Once the Machine Start Harness and the Ethernet Cables are ran through the rectangular opening in the brackets, secure the brackets in place by inserting the reader and attaching with C-0141 Screws.

  6. Insert C-0926 Drop Cover into the coin drop opening. Secure in place using C-1044N Kep Nuts.

  7. Apply C-0032 Coin Drop Label to the front of the Drop Cover.