3607 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer Extractor
Manufacturer: Laundrylux
Make: Wascomat
Model Length: Not Set

Associated Models


WSD765
WSD765CC
WSD780
WSD780CC

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Connect Power

 I-P0003

Part #: C-5101

Desc 1: Spade Taps

Desc 2: 18-14 AWG

   Qty: 3

Part #: C-5210

Desc 1: Power Adapter Harness

Desc 2: CGI

   Qty: 1

Part #: C-5500

Desc 1: Power Extension Harness

Desc 2: 25.5"

   Qty: 1

Part #: C-5602R1

Desc 1: Power Converter

Desc 2: SMT-012-018VW

   Qty: 1

  1. Tap power as described in the Fascard Reader Install - Universal Concepts document using the C-5101 Spade Taps provided.

  2. Connect the C-5210 Power Adapter Harness to the installed spade taps. Connect the opposite end to the C-5602 Power Converter.

  3. Connect the C-5500 Power Extension Harness to the appropriate connector on the C-5602 Power Converter. The remaining cable end connects to the FasCard reader.

Connect Machine Interface Harness

 I-T0076

Part #: C-0126-MLV

Desc 1: Machine Start Harness (SA)

Desc 2: Wascomat Compass

   Qty: 1

Part #: C-0126-MLV-EXT15

Desc 1: Extension Harness

Desc 2: Compass

   Qty: 1

Part #: C-5359

Desc 1: Machine Start Harness (SA)

Desc 2: Compass

   Qty: 1

  1. Connect the C-0126-MLV Machine Start Harness to the RS-232 port on the Machine Control Assembly.

    1. If extra length is needed on the harness, attach C-0126-MLV-EXT15 Extension Harness.

  2. Connect the C-5359 Machine Start Harness to the Input port on the Machine Control Assembly.