3677 Reader Install Guide

Warning!

This document assumes the installer has working knowledge of hand tools and of the target machine in question. Physical modification of machine may be required, including modification of machine panels and internal modification to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to target machine.

Overview

Equipment Details

Type: Washer Extractor
Manufacturer: Tolon
Make: Tolon
Model Length: 5

If sending multiple relay pulses to start machine, increase interval to 300ms or longer.

Associated Models


TWE10
TWE15
TWE18
TWE24
TWE28
TWE40

Recommended Tools and Supplies

  • Drill

  • 1 1/8" Tungsten Carbide Tipped Hole Cutter

  • Cutting Oil

  • 9/64" Drill Bit

  • Center Punch

  • Hammer

  • Fine Point Permanent Marker

  • Pliers

  • Tape Measure

Installation

Connect Power

 I-P0031

Part #: C-6206

Desc 1: F2/F3, Power Hrns - Tolon

Desc 2:

   Qty: 1

  1. Connect the C-6206 Power Adapter Harness to the 24VDC Transformer.

    1. Connect the black wire to the '-' negative terminal.

    2. Connect the red wire to the '+' positive terminal.

Connect Coin Sense Harness

 I-S0018

Part #: C-5360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect the Red, Blue, and Green wires from the coin drop termination block spade connections and connect the C-5360 Coin Sense Harness in place of the disconnected wires, matching the corresponding colors.

 I-S0046

Part #: C-6360

Desc 1: Coin Sense Harness

Desc 2: Female taps, Rq. Male

   Qty: 1

  1. Disconnect coin drop from factory machine harness.

  2. Connect C-6360 Coin Sense Harness to the coin drop.

    1. Connect red to red.

    2. Connect green to brown.

    3. Connect blue to blue.

Connect Machine Interface Harness

 I-T0040

Part #: C-5256

Desc 1: Machine Start Harns (pulse)

Desc 2: 20" - Male taps, Rq. Female

   Qty: 1

  1. Connect the C-5256 Machine Start Harness to the harness originally connected to the coin drop.

    1. Connect to the black and brown wires.

    2. To prevent any potential electrical issues, apply electrical tape over the blue wire connector.