How-to reset a Microtik Hex Lite LCRF

If an installed LCRF experiences a problem and is no longer operational, the LCRF can be returned to the CCI 'BootStrap' configuration by performing a hardware reset. This hardware reset is accomplished with the following sequence:

Step-by-step guide

Static IP Warning

On LCRFs configured with a static IP, before proceeding make sure that the ISP modem/router are configured to automatically give out IP addresses (DHCP).

If DHCP is not enabled on the modem/router then the LCRF will be unable to obtain an IP address after it is reset. This means it will not be able to download the full configuration from the datacenter and will be unusable.

  1. Disconnect power from the LCRF.

  2. Press and hold the ‘RES’ reset button.

  3. Reconnect power to the LCRF.

  4. Wait until the (USR Light or Green Light) starts flashing.

  5. Release the 'RES' reset button.

  6. Keep the LCRF powered on.

This reset operation will configure the LCRF to the initial CCI "BootStrap" configuration.

  • The LCRF will then automatically download and install the latest ‘operational’ configuration.

  • During this sequence, it is important to keep the LCRF powered on. This procedure may take up to 15 minutes.

  • After the downloads and installation are completed, the LCRF will automatically become operational.

Check with your CCI technician if the factory reset was successful.



If you wait until LED stops flashing, and only then release the button - this will instead launch Netinstall mode, to reinstall RouterOS.