FasCard F3 Reader Field Replaceable Component Guide

FasCard F3 Reader Field Replaceable Component Guide

Overview

This page covers all available components that can be replaced on a third-generation FasCard reader (F3).

Part List

Part IDDescriptionImage
C-5411

Gasket

P8306 x 4.55" x 3.895"

for F2/F3 bezel

C-5510

Main Housing

Build F3

C-5511

LCD Bezel

Build F3

C-5512

Read Head Keeper

Build F3

C-5513

Light Pipe

Build F3

C-5514

Bezel Label

Build F2E and F3

C-5515

Chip Reader Label

Build F3

C-5517

F3 LCD Display

Build F2E and F3

C-5523

F3 LCD bezel w/ screen

and overlay label

Display + Bezel assembly

Step-by-step guide

This document assumes the installer has working knowledge of hand tools and of the target equipment in question. Physical modification of the equipment may be required, including modifications to equipment panels and internal components to accommodate cables or harnesses.

It is recommended that the instructions contained herein be performed by individuals who are qualified to perform these tasks. Card Concepts Inc. takes no responsibility for the accuracy of this document or for any damage that may occur to the target equipment.

Part IDDescriptionImage
C-5514

Bezel Label

C-5517

F3 LCD Display

C-5523

F3 LCD bezel w/ screen

Step 1 - Remove the F3 Reader from its mount

  1. Locate and remove the C-5416 security screws underneath the F3 reader.

  2. Gently pull the bottom of the reader forward until it clears the bottom of the mounting bracket. 

  3. Lift the top of the reader clear of the mounting bracket. 

  4. Disconnect all harnesses connected to the reader. 

    Fig. 1c

Step 2 - Disconnect the reader housing from the housing plate

  1. Identify and remove the four (4) Philips screws. 

    Fig. 2b
  2. Gently push the housing plate (with the control board and VP3300 attached) out from the main reader housing. 

  3. Do not pull the housing plate away from the main reader housing, as the MSR cable will still be connected on the side.

    IMG_1361.jpeg
  4. Optional: You can disconnect the MSR cable by pulling on the gray tabs from the main reader housing.

    thumbnail_IMG_1362.jpg

Step 3 - Disconnecting the display from the Control Board

  1. Pull the black tabs on both sides of the display cable out to remove it. 

  2. Using a flathead screwdriver, pull the interface cable out. There will be some resistance when pulling on the cable.

    IMG_1363.jpeg
  3. You can now move the Control Board to the side of the housing plate. Take caution as the VP3300 cable is still connected.

    1. Be sure to place the Control Board on an anti-static surface.

      IMG_1364.jpeg

Step 4 - Mounting the display to the housing plate

  1. Peel off the F3 bezel cover (C-5514) from the reader housing plate.

  2. Take off the LCD screen (C-5517) from the housing plate. Be sure to fully remove the cables from the slot.

  3. Place the replacement LCD screen (C-5517) on the reader housing plate. Be sure to slide the display cables through the provided slot.

    IMG_1366.jpeg
  4. Your reader should look like this with the replacement LCD screen (C-5517) on the housing plate:

    IMG_1365.jpeg
  5. Replace the F3 reader bezel (C-5514).

Step 5 - Connect the housing plate to the main reader housing

  1. Reconnect the LCD display and secure the ribbon cable clip to lock the cable into position.

  2. Reconnect the touchscreen interface cable by pushing the tip of the cable into its connector. Stop pushing once the cable feels secure.

  3. Slide the reader screen, housing plate, and control board back into the gray reader housing bracket. To do this:

    1. Slide the bottom half of the reader into the bracket first.

    2. Then push the top half into position.

      1. Take caution with the LCD and MSR cables as they may get caught between the housing bracket and the reader housing plate from the top and side.

    3. Pushing down slightly on the VP3300 unit will give some space to the cables to fit in the top half of the bracket.

Step 6 - Securing the reader and verifying functionality

  1. Locate the four (4) screws you removed earlier in Step 1 and reapply them to the reader housing plate and bracket.

    Fig. 2b
  2. Connect the power cable to the reader to confirm operability.

    1. If the screen is not working properly, troubleshoot accordingly.

  3. Remount the reader onto the machine. 

    1. Refer to FasCard F2/F3 Reader Installation Guide - High-Front & Top-Mount, or;

    2. Refer to FasCard F2/F3 Reader Installation Guide - Front Mount.