_861

 I-M0123

Part #: C-1059

Desc 1: Nut

Desc 2: 10-32 - Kep

   Qty: 2

Part #: C-1070-W

Desc 1: Washer - Build: XCH

Desc 2: 1/4" x 1" O.D.

   Qty: 2

Part #: C-5760-A

Desc 1: Alliance Adapter Bracket

Desc 2: Mounts C-5760 to MeterCase

   Qty: 1

Part #: C-6762

Desc 1: Metercase Bracket

Desc 2: Coin Slide Ready Machine

   Qty: 1

Part #: C-5365

Desc 1: Bypass Harness

Desc 2: Alliance Coin Vault Bypass

   Qty: 1

Part #: C-5420

Desc 1: Screw

Desc 2: 10-32 x ¼" - Pan

   Qty: 2

Part #: C-5416

Desc 1: Screw

Desc 2: 8-32" x 3/8" - Button - Torx

   Qty: 2

Part #: C-5414

Desc 1: F2/F3 Std. Mounting Bracket

Desc 2: Sheet metal base

   Qty: 1

  1. Remove the coin drop and coin box.

  2. Remove Vault Switch and bridge the wires previously connected to the Vault Switch with the C-5365 Bypass Harness.

  3. Secure C-5414 F2 Mounting Bracket to the C-6903 Mounting Bracket using the (2) C-5420 Screws.

  4. Attach the C-5760-A Adapter Bracket to the C-6762 Mounting Bracket to the captured nut on the inside of the C-6762 Mounting Bracket.

  5. Run all reader harnesses through the metercase and out the opening where the coin drop normally mounts.

  6. Run all reader harnesses through the circular opening on the C-6762 Mounting Bracket.

  7. Install the C-6762 Mounting Bracket into the front opening of the metercase so the two threaded posts of the C-5760-A Adapter Bracket line up with the openings for the coin slots.

    1. Secure to the metercase using the (2) C-1059 Kep Nuts and (2) C-1070-W Washers.