_1054
- Chris Kite
Part #: C-0133
Desc 1: Standoff
Desc 2: 8-32" x 1-1/2" - Hex
Qty: 2
Part #: C-0141
Desc 1: Screw
Desc 2: 8-32 x 1-1/2" - Cap
Qty: 2
Part #: C-0015
Desc 1: Label
Desc 2: Reader Cover Label
Qty: 1
Part #: C-0906
Desc 1: Spacer Plate
Desc 2: 5 1/2" x 4 3/8"
Qty: 1
Part #: C-0936
Desc 1: Vault Mount Bracket
Desc 2:
Qty: 1
Part #: C-5035
Desc 1: Label
Desc 2: 3-7/8" x 3-1/4"
Qty: 1
Remove existing coin box and coin drop.
Bend the side tabs of the C-0936 Vault Bracket outward and install into the coin vault. The tabs should snap into place securing the bracket.
Attach the (2) C-0133 8-32 x 1-1/2" Hex Standoffs to the C-0936 Vault Bracket.
Run the ethernet cables and start harness through the coin vault opening and C-0936 Vault Bracket.
Before attaching the reader to the C-0936 Vault Bracket remove the protective film from the C-0906 Spacer Plate and place between the reader and the machine's front panel so it aligns with the C-0936 Vault Bracket openings.
Attach the reader to the (2) C-0133 8-32 x 1-1/2" Hex Standoffs using the (2) C-0141 8-32 x 1-1/2" Socket Screws.
Once installation is complete and the reader has been setup and tested, apply the C-0015 label over the front of the reader.
Apply the C-5035 Label over the coin drop opening.